说明 | CDL1 | CDL2 | CDL3 | CDL4 | CDL8 | CDL16 | CDL32 | CDL42 | CDL65 | CDL85 |
额定流量【m3/h】 | 1 | 2 | 3 | 4 | 8 | 16 | 32 | 42 | 65 | 85 |
额定流量【l/s】 | 0.28 | 0.56 | 0.83 | 1.1 | 2.2 | 4.4 | 8.9 | 11.7 | 18 | 24 |
流量范围【m3/h】 | 0.4-2 | 1-3.5 | 1.2-4 | 1.5-8 | 5-12 | 8-22 | 16-40 | 25-55 | 30-80 | 50-110 |
流量范围【l/s】 | 0.11-0.56 | 0.28-0.97 | 0.33-1.1 | 0.42-2.2 | 1.4-3.3 | 2.2-6.1 | 4.4-11.1 | 6.9-15.3 | 8.3-22.2 | 13.8-30.5 |
最大压力【bar】 | 21 | 23 | 22 | 21 | 21 | 22 | 26 | 30 | 22 | 17 |
电机功率【kw】 | 0.37-2.2 | 0.37-3 | 0.37-3 | 0.37-4 | 0.75-7.5 | 2.2-15 | 1.5-30 | 3.0-45 | 4.0-45 | 5.5-45 |
温度范围【℃】 | -15-+120 | |||||||||
最高功率【%】 | 44 | 46 | 54 | 59 | 64 | 70 | 76 | 78 | 80 | 81 |
| 类型 | ||||||||||
CDL | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
CDLF | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| CDL管路联接 | ||||||||||
DIN法兰 | DN25 | DN25 | DN25 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 | DN100 |
椭圆法兰 | G1 | G1 | G1 | G1 1/4 | G1 1/2 | |||||
| CDLF管路联接 | ||||||||||
DIN法兰 | DN25 | DN25 | DN25 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 | DN100 |
卡套接头 | ● | ● | ● | ● | ● | ● | ||||
管螺纹 | ● | ● | ● | ● | ● | ● | ||||
应用
CDL/CDLF是一种多功能产品,可以输送从自来水到工业液体的各种不同介质,适应于不同温度、流量和压力范围,CDL适用于无腐蚀性液体,CDLF适用于轻度腐蚀性液体。
供水:水厂过滤与输送、水厂分区送水、主管增压、高层建筑增压。
工业增压:流程水系统、清洗系统、高压冲洗系统、消防系统。
工业液体输送:冷却和空调系统、锅炉给水和冷凝系统、机床配套、酸和碱。
水处理:超滤系统、反渗透系统、蒸馏系统、分离器、游泳池。
灌溉:农田灌溉、喷灌、滴灌。
运行条件
稀薄、干净、非易燃易爆并不含固体颗粒或纤维的液体。
液体温度:常温型 -15℃至—+70℃
热水型 +70℃至+120℃
环境温度:最高+40℃
海拔:最高1000m
泵
CDL/CDLF为安装标准电机的非自吸立式多级离心泵,电机轴通过泵头用联轴器直接与泵轴联接,拉杆螺栓将耐压筒、过流部件固定在泵头和进出水段之间,泵进出水口在泵底同一直线上;本泵可根据需要配置智能保护器,对泵干转、缺相、过载等进行有效保护。</p>
电机
电机为全封闭,风冷式二极标准电机。
防护等级:IP55
绝缘等级:F
标准电压,50Hz:1x220-230/240V
3x200-220/346-380V
3x220-240/380-415V
3x380-415V